sane-test(5)             SANE Scanner Access Now Easy             sane-test(5)

NAME
       sane-test - SANE backend for testing frontends

DESCRIPTION
       The sane-test library implements a SANE (Scanner Access Now Easy) back‐
       end  that  allows testing the SANE installation and SANE frontends.  It
       provides access to a (nearly)  unlimited  number  of  virtual  devices.
       There is no support for real scanners or cameras.  However, the backend
       simulates scanning and setting options.

       The idea is not only to find bugs in frontends but also to show all ca‐
       pabilities  of  SANE.  Therefore sane-test implements functions and op‐
       tions that are not (or seldom) found in other backends.

       The backend is commented out in  /etc/sane.d/dll.conf,  so  either  the
       comment character must be removed or the backend must be called explic‐
       itly.  E.g.  scanimage -d test or xscanimage test.



SCAN MODE OPTIONS
       Option mode selects the scan mode (Gray or Color).

       Option  depth  determines  the number of bits per sample (1. 8, or 16).
       Keep in mind, that this value refers to the sample, not the pixel.   So
       depth=16  results  in  48  bits per pixel in color mode. The most usual
       combinations are mode=Gray, depth=1 for lineart, mode=Gray, depth=8 for
       gray and mode=Color, depth=8 for color mode.  The combination of  color
       and  1-bit  mode  is  quite  obscure (8 colors) but allowed in the SANE
       standard. However, the meaning of bits is not defined.  Currently  1  =
       high intensity and 0 = low intensity is used.

       Setting option hand-scanner results in the test-backend behaving like a
       hand-scanner.   Hand-scanners  do  not  know the image height a priori.
       Instead, they return a height of -1.  Setting this option allows one to
       test whether a frontend can handle this correctly.   This  option  also
       enables a fixed width of 11 cm.

       Setting  option three-pass simulates a three-pass scanner.  Older color
       scanners needed to scan the image once per  color  (red/green/blue)  to
       get  the  full  image.  Therefore, in this mode three single frames are
       transmitted in color mode.

       Option three-pass-order provides support for changing the order of  the
       three  frames (see option three-pass above).  A frontend should support
       all orders.

       Option resolution sets the resolution of the image in dots per inch.

       Option source can be used to  simulate  an  Automatic  Document  Feeder
       (ADF). After 10 scans, the ADF will be "empty".

SPECIAL OPTIONS
       Option  test-picture allows one to set the image that's returned to the
       frontend.  While "Solid white" and "Solid black" are quite obvious, the
       other options need some more explanation.  Color patterns are  used  to
       determine  if  all  modes and their colors are represented correctly by
       the frontend.  The grid should look like the same  in  every  mode  and
       resolution.   A  table  of  all  the  test  pictures  can  be found at:
       http://www.meier-geinitz.de/sane/test-backend/test-pictures.html.

       If option invert-endianness is set, the upper and lower bytes of  image
       data  in  16  bit modes are exchanged.  This option can be used to test
       the 16 bit modes of frontends, e.g. if the frontend  uses  the  correct
       endianness.

       If  option  read-limit  is  set, the maximum amount of data transferred
       with each call to sane_read() is limited.

       Option read-limit-size sets the limit for  option  read-limit.   A  low
       limit slows down scanning.  It can be used to detect errors in frontend
       that  occur  because  of wrong assumptions on the size of the buffer or
       timing problems.

       Option read-delay enables delaying data to the frontend.

       Option read-delay-duration selects the number of microseconds the back‐
       ends waits after each transfer of a buffer.  This option is  useful  to
       find timing-related bugs, especially if used over the network.

       If  option  read-return-value is different from "Default", the selected
       status will be returned by every call to sane_read().  This  is  useful
       to test the frontend's handling of the SANE statuses.

       If  option  ppl-loss  is  different from 0, it determines the number of
       pixels that are "lost" at the end of each line.  That means, lines  are
       padded with unused data.

       Option fuzzy-parameters selects that fuzzy (inexact) parameters are re‐
       turned  as  long  as  the scan hasn't been started.  This option can be
       used to test if the frontend uses the  parameters  it  got  before  the
       start of the scan (which it shouldn't).

       Option  non-blocking  determines  if  non-blocking  IO  for sane_read()
       should be used if supported by the frontend.

       If option select-fd is set, the backend offers a select  filedescriptor
       for detecting if sane_read() will return data.

       If  option enable-test-options is set, a fairly big list of options for
       testing the various SANE option types is enabled.

       Option print-options can be used to print a  list  of  all  options  to
       standard error.

GEOMETRY OPTIONS
       Option tl-x determines the top-left x position of the scan area.

       Option tl-y determines the top-left y position of the scan area.

       Option br-x determines the bottom-right x position of the scan area.

       Option br-y determines the bottom-right y position of the scan area.

BOOL TEST OPTIONS
       There  are  6  bool  test  options  in total.  Each option is numbered.
       (3/6) means: this is option 3 of 6.  The numbering scheme  is  intended
       for  easier detection of options not displayed by the frontend (because
       of missing support or bugs).

       Option bool-soft-select-soft-detect (1/6) is a bool  test  option  that
       has  soft  select  and soft detect (and advanced) capabilities.  That's
       just a normal bool option.

       Option bool-hard-select-soft-detect (2/6) is a bool  test  option  that
       has  hard  select  and  soft  detect (and advanced) capabilities.  That
       means the option can't be set by the frontend but by the user (e.g.  by
       pressing a button at the device).

       Option  bool-hard-select  (3/6) is a bool test option that has hard se‐
       lect (and advanced) capabilities.  That means the option can't  be  set
       by  the  frontend but by the user (e.g. by pressing a button at the de‐
       vice) and can't be read by the frontend.

       Option bool-soft-detect (4/6) is a bool test option that has  soft  de‐
       tect (and advanced) capabilities.  That means the option is read-only.

       Option  bool-soft-select-soft-detect-emulated  (5/6) is a Bool test op‐
       tion that has soft select, soft detect, and emulated (and advanced) ca‐
       pabilities.

       Option bool-soft-select-soft-detect-auto (6/6) is a  Bool  test  option
       that  has  soft select, soft detect, and automatic (and advanced) capa‐
       bilities.  This option can be automatically set by the backend.

INT TEST OPTIONS
       There are 7 int test options in total.

       Option int (1/7) is an int test option with no unit and  no  constraint
       set.

       Option int-constraint-range (2/7) is an int test option with unit pixel
       and constraint range set.  Minimum is 4, maximum 192, and quant is 2.

       Option  int-constraint-word-list  (3/7) is an int test option with unit
       bits and constraint word list set.

       Option int-constraint-array (4/7) is an int test option  with  unit  mm
       and using an array without constraints.

       Option  int-constraint-array-constraint-range  (5/7) is an int test op‐
       tion with unit mm and using an array with a range constraint.   Minimum
       is 4, maximum 192, and quant is 2.

       Option  int-constraint-array-constraint-word-list  (6/7) is an int test
       option with unit percent and using an array or word list constraint.

       Option int-inexact (7/7) is an int test option that increments the  re‐
       quested value and returns flag SANE_INFO_INEXACT.



FIXED TEST OPTIONS
       There are 3 fixed test options in total.

       Option  fixed  (1/3)  is  a  fixed test option with no unit and no con‐
       straint set.

       Option fixed-constraint-range (2/3) is a fixed test  option  with  unit
       microsecond  and  constraint  range  set.  Minimum  is  -42.17, maximum
       32767.9999, and quant is 2.0.

       Option fixed-constraint-word-list (3/3) is a fixed test option with  no
       unit and constraint word list set.

STRING TEST OPTIONS
       There are 3 string test options in total.

       Option string (1/3) is a string test option without constraint.

       Option string-constraint-string-list (2/3) is a string test option with
       string list constraint.

       Option string-constraint-long-string-list (3/3) is a string test option
       with string list constraint. Contains some more entries...

BUTTON TEST OPTION
       Option button (1/1) is a Button test option. Prints some text...

FILES
       /etc/sane.d/test.conf
              The   backend   configuration  file  (see  also  description  of
              SANE_CONFIG_DIR below). The initial values of most of the  basic
              SANE options can be configured in this file. A template contain‐
              ing  all the default values is provided together with this back‐
              end. One of the more interesting  values  may  be  number_of_de‐
              vices.  It can be used to check the frontend's ability to show a
              long  list  of devices.  The config values concerning resolution
              and geometry can be useful to test  the  handling  of  big  file
              sizes.


       /usr/lib/x86_64-linux-gnu/sane/libsane-test.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-test.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).


ENVIRONMENT
       SANE_CONFIG_DIR
              This environment variable specifies the list of directories that
              may contain the configuration file.  On *NIX systems, the direc‐
              tories are separated by a colon (`:'), under OS/2, they are sep‐
              arated  by a semi-colon (`;').  If this variable is not set, the
              configuration file  is  searched  in  two  default  directories:
              first,   the   current  working  directory  (".")  and  then  in
              /etc/sane.d.  If the value of the environment variable ends with
              the directory separator character, then the default  directories
              are  searched  after  the explicitly specified directories.  For
              example, setting SANE_CONFIG_DIR to "/tmp/config:" would  result
              in directories tmp/config, ., and /etc/sane.d being searched (in
              this order).

       SANE_DEBUG_TEST
              If the library was compiled with debug support enabled, this en‐
              vironment  variable  controls  the debug level for this backend.
              Higher debug levels increase the verbosity of the output.

              Example: export SANE_DEBUG_TEST=4


SEE ALSO
       sane(7), scanimage(1), xscanimage(1)
       http://www.meier-geinitz.de/sane/test-backend/



AUTHOR
       Henning Meier-Geinitz <henning@meier-geinitz.de>


BUGS
       - config file values aren't tested for correctness