SMARTD.CONF(5)              SMART Monitoring Tools              SMARTD.CONF(5)

NAME
       smartd.conf - SMART Disk Monitoring Daemon Configuration File


DESCRIPTION
       [This man page is generated for the Linux version of smartmontools.  It
       does not contain info specific to other platforms.]

       /etc/smartd.conf is the configuration file for the smartd daemon.

       If  the configuration file /etc/smartd.conf is present, smartd reads it
       at startup.  If smartd subsequently receives a HUP signal, it will then
       re-read the configuration file.  If smartd is running  in  debug  mode,
       then  an  INT  signal will also make it re-read the configuration file.
       This signal can be generated by typing <CONTROL-C> in the terminal win‐
       dow where smartd is running.

       In the absence of a configuration file smartd  will  try  to  open  all
       available  devices (see smartd(8) man page).  A configuration file with
       a single line 'DEVICESCAN -a' would have the same effect.

       This can be annoying if you have an ATA or SCSI device  that  hangs  or
       misbehaves when receiving SMART commands.  Even if this causes no prob‐
       lems,  you may be annoyed by the string of error log messages about de‐
       vices that can't be opened.

       One can avoid this problem, and gain more control  over  the  types  of
       events   monitored   by   smartd,   by  using  the  configuration  file
       /etc/smartd.conf.  This file contains a list  of  devices  to  monitor,
       with  one device per line.  An example file is included with the smart‐
       montools distribution.  You will find this sample configuration file in
       /usr/share/doc/smartmontools/.  For security,  the  configuration  file
       should  not  be writable by anyone but root.  The syntax of the file is
       as follows:

       •   There should be one device listed per line, although you  may  have
           lines that are entirely comments or white space.

       •   Any text following a hash sign '#' and up to the end of the line is
           taken to be a comment, and ignored.

       •   Lines  may  be  continued by using a backslash '\' as the last non-
           whitespace or non-comment item on a line.

       •   Note: a line whose first character is a hash sign '#' is treated as
           a white-space blank line, not as a non-existent line, and will  end
           a continuation line.

       Here  is an example configuration file.  It's for illustrative purposes
       only; please don't copy it onto your system without reading to the  end
       of the DIRECTIVES Section below!

       ################################################
       # This is an example smartd startup config file
       # /etc/smartd.conf
       #
       # On the second disk, start a long self-test every
       # Sunday between 3 and 4 am.
       #
       /dev/sda -a -m admin@example.com,root@localhost
       /dev/sdb -a -I 194 -I 5 -i 12 -s L/../../7/03
       #
       # Send a TEST warning email to admin on startup.
       #
       /dev/sdc -m admin@example.com -M test
       #
       # An ATA disk may appear as a SCSI device to the
       # OS.  If a SCSI to ATA Translation (SAT) layer
       # is between the OS and the device then this can be
       # flagged with the '-d sat' option.
       /dev/sda -a -d sat
       #
       # Disks connected to a MegaRAID controller
       # Start short self-tests daily between 1-2, 2-3, and
       # 3-4 am.
       # Linux:
       /dev/sda -d megaraid,0 -a -s S/../.././01
       /dev/sda -d megaraid,1 -a -s S/../.././02
       /dev/sda -d megaraid,2 -a -s S/../.././03
       /dev/bus/0 -d megaraid,2 -a -s S/../.././03
       #
       # Three disks connected to an AacRaid controller
       # Start short self-tests daily between 1-2, 2-3, and
       # 3-4 am.
       /dev/sda -d aacraid,0,0,66 -a -s S/../.././01
       /dev/sda -d aacraid,0,0,67 -a -s S/../.././02
       /dev/sda -d aacraid,0,0,68 -a -s S/../.././03
       #
       # Two SATA (not SAS) disks on a 3ware 9750 controller.
       # Start long self-tests Sundays between midnight and
       # 1 am and 2-3 am
       # under Linux
       /dev/twl0 -d 3ware,0 -a -s L/../../7/00
       /dev/twl0 -d 3ware,1 -a -s L/../../7/02
       #
       # Two disks connected to the first HP SmartArray controller
       # which uses the Linux cciss driver.  Start long self-tests
       # on Sunday nights and short self-tests every night and send
       # errors to root.
       /dev/sda -d cciss,0 -a -s (L/../../7/02|S/../.././02) -m root
       /dev/sda -d cciss,1 -a -s (L/../../7/03|S/../.././03) -m root
       #
       # Monitor 2 disks connected to the first HP SmartArray controller which
       # uses the cciss driver. Start long tests on Sunday nights and short
       # self-tests every night and send errors to root
       #  /dev/sda -d cciss,0 -a -s (L/../../7/02|S/../.././02) -m root
       #  /dev/sda -d cciss,1 -a -s (L/../../7/03|S/../.././03) -m root
       #
       # Three SATA disks on a HighPoint RocketRAID controller.
       # Start short self-tests daily between 1-2, 2-3, and
       # 3-4 am.
       # under Linux
       /dev/sde -d hpt,1/1 -a -s S/../.././01
       /dev/sde -d hpt,1/2 -a -s S/../.././02
       /dev/sde -d hpt,1/3 -a -s S/../.././03
       #
       # Two SATA disks connected to a HighPoint RocketRAID
       # via a pmport device.  Start long self-tests Sundays
       # between midnight and 1 am and 2-3 am.
       # under Linux
       /dev/sde -d hpt,1/4/1 -a -s L/../../7/00
       /dev/sde -d hpt,1/4/2 -a -s L/../../7/02
       #
       # Three SATA disks connected to an Areca
       # RAID controller.  Start long self-tests Sundays
       # between midnight and 3 am.
       # under Linux
       /dev/sg2 -d areca,1 -a -s L/../../7/00
       /dev/sg2 -d areca,2 -a -s L/../../7/01
       /dev/sg2 -d areca,3 -a -s L/../../7/02
       #
       # The following line enables monitoring of the
       # ATA Error Log and the Self-Test Error Log.
       # It also tracks changes in both Prefailure
       # and Usage Attributes, apart from Attributes
       # 9, 194, and 231, and shows  continued lines:
       #
       /dev/sdd -l error \
            -l selftest \
            -t \         # Attributes not tracked:
            -I 194 \     # temperature
            -I 231 \     # also temperature
            -I 9         # power-on hours
       #
       ################################################

       If  a  cciss  controller  is  used  then the corresponding block device
       (/dev/sd?) must be listed, along with the ´-d cciss,N´  Directive  (see
       below).

       DEVICESCAN
              If  a  non-comment  entry  in the configuration file is the text
              string DEVICESCAN in capital letters, then  smartd  will  ignore
              any remaining lines in the configuration file, and will scan for
              devices.   If DEVICESCAN is not followed by any Directives, then
              '-a' will apply to all devices.

       DEVICESCAN may optionally be followed by Directives that will apply  to
       all devices that are found in the scan.  For example

         DEVICESCAN -m root@example.com

       will  scan  for  all  devices, and then monitor them.  It will send one
       email warning per device for any problems that are found.

         DEVICESCAN -H -m root@example.com

       will do the same, but only monitors the SMART health status of the  de‐
       vices, rather than the default '-a'.

       Multiple  '-d TYPE' options may be specified with DEVICESCAN to combine
       the scan results of more than one TYPE.

       Configuration entries for specific devices may precede  the  DEVICESCAN
       entry.  For example

         DEFAULT -m root@example.com
         /dev/sda -s S/../.././02
         /dev/sdc -d ignore
         DEVICESCAN -s L/../.././02

       will  scan  for all devices except /dev/sda and /dev/sdc, monitor them,
       and run a long test between 2–3 am every morning.  Device /dev/sda will
       also be monitored, but only a short test will be run.  Device  /dev/sdc
       will  be  ignored.   Warning  emails will be sent for all monitored de‐
       vices.

       A device is ignored by DEVICESCAN if a configuration line with the same
       device name exists.  Symbolic links are resolved before this  check  is
       done.   A device name is also ignored if another device with same iden‐
       tify information (vendor, model, firmware version, serial number,  WWN)
       already exists.


DEFAULT SETTINGS
       If  an entry in the configuration file starts with DEFAULT instead of a
       device name, then all directives in this entry are set as defaults  for
       the next device entries.

       This configuration:

         DEFAULT -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
         /dev/sda
         /dev/sdb
         /dev/sdc
         DEFAULT -H -m admin@example.com
         /dev/sdd
         /dev/sde -d removable

       has the same effect as:

         /dev/sda -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
         /dev/sdb -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
         /dev/sdc -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
         /dev/sdd -H -m admin@example.com
         /dev/sde -d removable -H -m admin@example.com


CONFIGURATION FILE DIRECTIVES
       The  following  are the Directives that may appear following the device
       name or DEVICESCAN or DEFAULT on any line of the /etc/smartd.conf  con‐
       figuration  file.   Note  that  these  are NOT command-line options for
       smartd.  The Directives below may appear in any  order,  following  the
       device name.

       For  an  ATA  device,  if no Directives appear, then the device will be
       monitored as if the '-a' Directive (monitor all SMART  properties)  had
       been given.

       If  a  SCSI  disk is listed, it will be monitored at the maximum imple‐
       mented level: roughly equivalent to using the '-H -l selftest'  options
       for  an  ATA disk.  So with the exception of '-d', '-m', '-l selftest',
       '-s', and '-M', the Directives below are ignored for SCSI  disks.   For
       SCSI  disks, the '-m' Directive sends a warning email if the SMART sta‐
       tus indicates a disk failure or problem, if the SCSI inquiry about disk
       status fails, or if new errors appear in the self-test log.

       If a 3ware controller is used then the corresponding SCSI (/dev/sd?) or
       character device (/dev/twe?, /dev/twa?, /dev/twl? or /dev/tws?) must be
       listed, along with the '-d 3ware,N' Directive (see below).   The  indi‐
       vidual  ATA  disks  hosted  by the 3ware controller appear to smartd as
       normal ATA devices.  Hence all the ATA directives can be used for these
       disks (but see note below).

       If an Areca controller is used  then  the  corresponding  device  (SCSI
       /dev/sg?  on  Linux  or  /dev/arcmsr0 on FreeBSD) must be listed, along
       with the '-d areca,N' Directive (see below).  The individual SATA disks
       hosted by the Areca controller appear to smartd as normal ATA  devices.
       Hence  all  the  ATA  directives  can  be  used for these disks.  Areca
       firmware version 1.46 or later which  supports  smartmontools  must  be
       used; Please see the smartctl(8) man page for further details.

       -d TYPE
              Specifies  the  type of the device.  The valid arguments to this
              directive are:

              auto - attempt to guess the device type from the device name  or
              from  controller  type  info provided by the operating system or
              from a matching USB ID entry in the drive database.  This is the
              default.

              ata - the device type is ATA.  This prevents smartd from issuing
              SCSI commands to an ATA device.

              scsi - the device type is SCSI.  This prevents smartd from issu‐
              ing ATA commands to a SCSI device.

              nvme[,NSID] - the device type is NVM Express  (NVMe).   The  op‐
              tional parameter NSID specifies the namespace id (in hex) passed
              to  the  driver.  Use 0xffffffff for the broadcast namespace id.
              The default for NSID is the namespace id addressed by the device
              name.

              sat[,auto][,N] - the device type  is  SCSI  to  ATA  Translation
              (SAT).   This  is for ATA disks that have a SCSI to ATA Transla‐
              tion Layer (SATL) between the disk  and  the  operating  system.
              SAT  defines  two  ATA  PASS THROUGH SCSI commands, one 12 bytes
              long and the other 16 bytes long.  The default is  the  16  byte
              variant  which  can be overridden with either '-d sat,12' or '-d
              sat,16'.

              If '-d sat,auto' is specified, device  type  SAT  (for  ATA/SATA
              disks)  is  only  used  if  the SCSI INQUIRY data reports a SATL
              (VENDOR: "ATA     ").  Otherwise device type SCSI (for  SCSI/SAS
              disks) is used.

              usbasm1352r,PORT  -  [NEW  EXPERIMENTAL SMARTD 7.4 FEATURE] this
              device type is for one or two SATA disks that are behind an  AS‐
              Media ASM1352R USB to SATA (RAID) bridge.  The parameter PORT (0
              or 1) selects the disk to monitor.
              Note: This USB bridge also supports '-d sat'.  This monitors ei‐
              ther  the  first disk or the second disk if no disk is connected
              to the first port.

              usbcypress - this device type is for ATA disks that are behind a
              Cypress USB to PATA bridge.  This will use the ATACB proprietary
              scsi pass through command.  The default SCSI operation  code  is
              0x24,  but  although  it  can  be  overridden  with  '-d  usbcy‐
              press,0xN', where N is the scsi operation code,  you're  running
              the risk of damage to the device or filesystems on it.

              usbjmicron[,p][,x][,PORT]  -  this device type is for SATA disks
              that are behind a JMicron USB to PATA/SATA bridge.   The  48-bit
              ATA  commands  (required e.g. for '-l xerror', see below) do not
              work with all of these bridges and are therefore disabled by de‐
              fault.  These commands can be enabled by '-d usbjmicron,x'.   If
              two  disks  are  connected  to a bridge with two ports, an error
              message is printed if no PORT (0 or 1) is specified.
              The PORT parameter is not necessary if the device  uses  a  port
              multiplier to connect multiple disks to one port.  The disks ap‐
              pear under separate /dev/ice names then.
              CAUTION:  Specifying ',x' for a device which does not support it
              results in I/O errors and may disconnect the  drive.   The  same
              applies if the specified PORT does not exist or is not connected
              to a disk.

              The Prolific PL2507/3507 USB bridges with older firmware support
              a pass-through command similar to JMicron and work with '-d usb‐
              jmicron,0'.  Newer Prolific firmware requires a modified command
              which can be selected by '-d usbjmicron,p'.  Note that this does
              not yet support the SMART status command.

              usbprolific - this device type is for SATA disks that are behind
              a Prolific PL2571/2771/2773/2775 USB to SATA bridge.

              usbsunplus  - this device type is for SATA disks that are behind
              a SunplusIT USB to SATA bridge.

              sntasmedia - [NEW EXPERIMENTAL SMARTD 7.3 FEATURE]  this  device
              type  is  for  NVMe disks that are behind an ASMedia USB to NVMe
              bridge.

              sntjmicron[,NSID] - this device type is for NVMe disks that  are
              behind  a  JMicron  USB  to NVMe bridge.  The optional parameter
              NSID specifies the namespace id (in hex) passed to  the  driver.
              The   default   namespace  id  is  the  broadcast  namespace  id
              (0xffffffff).

              sntrealtek - this device type is for NVMe disks that are  behind
              a Realtek USB to NVMe bridge.

              marvell - [Linux only] (deprecated and subject to remove).

              megaraid,N - [FreeBSD and Linux only] the device consists of one
              or  more SCSI/SAS disks connected to a MegaRAID controller.  The
              non-negative integer N (in the range of 0 to 127 inclusive)  de‐
              notes which disk on the controller is monitored.  This interface
              will  also  work  for  Dell  PERC controllers.  In log files and
              email messages this disk will be identified as megaraid_disk_XXX
              with XXX in the range from 000 to 127 inclusive.  Please see the
              smartctl(8) man page for further details.

              aacraid,H,L,ID - [Linux, Windows and  Cygwin  only]  the  device
              consists  of  one or more SCSI/SAS or SATA disks connected to an
              AacRaid controller.  The non-negative integers H,L,ID (Host num‐
              ber, Lun, ID) denote which disk on the controller is  monitored.
              In  log files and email messages this disk will be identified as
              aacraid_disk_HH_LL_ID.  Please see the smartctl(8) man page  for
              further details.

              3ware,N - [FreeBSD and Linux only] the device consists of one or
              more  ATA  disks connected to a 3ware RAID controller.  The non-
              negative integer N (in the range from 0 to  127  inclusive)  de‐
              notes  which  disk on the controller is monitored.  In log files
              and  email  messages   this   disk   will   be   identified   as
              3ware_disk_XXX with XXX in the range from 000 to 127 inclusive.

              Note  that  while  you may use any of the 3ware SCSI logical de‐
              vices /dev/tw* to address  any  of  the  physical  disks  (3ware
              ports),  error  and log messages will make the most sense if you
              always list the 3ware SCSI logical device corresponding  to  the
              particular  physical disks.  Please see the smartctl(8) man page
              for further details.

              areca,N - [FreeBSD, Linux, Windows and Cygwin only]  the  device
              consists  of  one  or more SATA disks connected to an Areca SATA
              RAID controller.  The positive integer N (in the range from 1 to
              24 inclusive) denotes which disk on the controller is monitored.
              In log files and email messages this disk will be identified  as
              areca_disk_XX  with  XX  in  the  range from 01 to 24 inclusive.
              Please see the smartctl(8) man page for further details.

              areca,N/E - [FreeBSD, Linux, Windows and Cygwin only] the device
              consists of one or more SATA or SAS disks connected to an  Areca
              SAS RAID controller.  The integer N (range 1 to 128) denotes the
              channel  (slot) and E (range 1 to 8) denotes the enclosure.  Im‐
              portant: This requires Areca  SAS  controller  firmware  version
              1.51 or later.

              cciss,N - [FreeBSD and Linux only] the device consists of one or
              more  SCSI/SAS  or  SATA  disks  connected  to a cciss RAID con‐
              troller.  The non-negative integer N (in the range from 0 to  15
              inclusive)  denotes  which  disk on the controller is monitored.
              In log files and email messages this disk will be identified  as
              cciss_disk_XX  with  XX  in  the  range from 00 to 15 inclusive.
              Please see the smartctl(8) man page for further details.

              hpt,L/M/N - [FreeBSD and Linux only] the device consists of  one
              or  more  ATA  disks  connected  to  a HighPoint RocketRAID con‐
              troller.  The integer L is the controller id, the integer  M  is
              the channel number, and the integer N is the PMPort number if it
              is  available.   The  allowed values of L are from 1 to 4 inclu‐
              sive, M are from 1 to 128 inclusive and N from 1 to 4 if  PMPort
              available.   And  also  these values are limited by the model of
              the HighPoint RocketRAID controller.  In  log  files  and  email
              messages  this disk will be identified as hpt_X/X/X and X/X/X is
              the same as L/M/N, note if no N indicated, N set to the  default
              value  1.   Please  see the smartctl(8) man page for further de‐
              tails.

              sssraid,E,S - [Linux only: NEW EXPERIMENTAL SMARTD 7.4  FEATURE]
              the  device  consists of one or more SCSI/SAS or SATA disks con‐
              nected to a SSSRAID controller.  The non-negative integer E  (in
              the range of 0 to 8) denotes the enclosure and S(range 0 to 128)
              denotes  the slot.  Please see the smartctl(8) man page for fur‐
              ther details.

              intelliprop,N[+TYPE] - (deprecated and subject to remove).

              jmb39x[-q],N[,sLBA][,force][+TYPE] - the device consists of mul‐
              tiple SATA disks connected to a JMicron JMB39x RAID port  multi‐
              plier.   The  suffix  '-q'  selects a slightly different command
              variant used by some QNAP NAS devices.  The  integer  N  is  the
              port  number  from  0 to 4.  Please see the smartctl(8) man page
              for further details.

              jms56x,N[,sLBA][,force][+TYPE] - the device consists of multiple
              SATA disks connected to  a  JMicron  JMS56x  USB  to  SATA  RAID
              bridge.  See 'jmb39x...' above for valid arguments.

              ignore - the device specified by this configuration entry should
              be  ignored.   This  allows one to ignore specific devices which
              are detected by a following DEVICESCAN configuration  line.   It
              may also be used to temporary disable longer multi-line configu‐
              ration  entries.  This Directive may be used in conjunction with
              the other '-d' Directives.

              removable - the device or its media is  removable.   This  indi‐
              cates  to  smartd  that  it should continue (instead of exiting,
              which is the default behavior) if the device does not appear  to
              be  present  when  smartd  is started.  This directive also sup‐
              presses warning emails and repeated log messages if  the  device
              is  removed  after  startup.  This Directive may be used in con‐
              junction with the other '-d' Directives.
              WARNING: Removing a device and connecting  a  different  one  to
              same interface is not supported and may result in bogus warnings
              until smartd is restarted.

       -n POWERMODE[,N][,q]
              [ATA  only]  This  'nocheck' Directive is used to prevent a disk
              from being spun-up when it is periodically polled by smartd.

              ATA disks have five different power states.   In  order  of  in‐
              creasing  power consumption they are: 'OFF', 'SLEEP', 'STANDBY',
              'IDLE', and 'ACTIVE'.  Typically in the OFF, SLEEP, and  STANDBY
              modes the disk's platters are not spinning.  But usually, in re‐
              sponse to SMART commands issued by smartd, the disk platters are
              spun up.  So if this option is not used, then a disk which is in
              a low-power mode may be spun up and put into a higher-power mode
              when it is periodically polled by smartd.

              Note  that  if the disk is in SLEEP mode when smartd is started,
              then it won't respond to smartd commands, and so the disk  won't
              be  registered  as a device for smartd to monitor.  If a disk is
              in any other low-power mode, then the commands issued by  smartd
              to register the disk will probably cause it to spin-up.

              The  '-n'  (nocheck)  Directive  specifies  if smartd's periodic
              checks should still be carried out when the device is in a  low-
              power mode.  It may be used to prevent a disk from being spun-up
              by  periodic  smartd  polling.   The allowed values of POWERMODE
              are:

              never - smartd will poll (check) the device  regardless  of  its
              power  mode.   This  may  cause  a disk which is spun-down to be
              spun-up when smartd checks it.  This is the default behavior  if
              the '-n' Directive is not given.

              sleep - check the device unless it is in SLEEP mode.

              standby  -  check  the  device  unless it is in SLEEP or STANDBY
              mode.  In these modes most disks are not  spinning,  so  if  you
              want  to  prevent  a laptop disk from spinning up each time that
              smartd polls, this is probably what you want.

              idle - check the device unless it is in SLEEP, STANDBY  or  IDLE
              mode.  In the IDLE state, most disks are still spinning, so this
              is probably not what you want.

              Maximum  number of skipped checks (in a row) can be specified by
              appending  positive  number  ',N'   to   POWERMODE   (like   '-n
              standby,15').  After N checks are skipped in a row, powermode is
              ignored and the check is performed anyway.

              When  a  periodic test is skipped, smartd normally writes an in‐
              formal log message.  The message can be suppressed by  appending
              the  option  ',q' to POWERMODE (like '-n standby,q').  This pre‐
              vents a laptop disk from spinning up due to this message.

              Both ',N' and ',q' can be specified together.

       -T TYPE
              Specifies how tolerant smartd should be of SMART  command  fail‐
              ures.  The valid arguments to this Directive are:

              normal  -  do  not  try to monitor the disk if a mandatory SMART
              command fails, but continue if an optional SMART command  fails.
              This is the default.

              permissive  - try to monitor the disk even if it appears to lack
              SMART capabilities.  This may be required  for  some  old  disks
              (prior  to  ATA-3  revision 4) that implemented SMART before the
              SMART standards were incorporated into the ATA/ATAPI  Specifica‐
              tions.  [Please see the smartctl -T command-line option.]

       -o VALUE
              [ATA  only]  Enables or disables SMART Automatic Offline Testing
              when smartd starts up and has no further effect.  The valid  ar‐
              guments to this Directive are on and off.

              The  delay  between  tests  is vendor-specific, but is typically
              four hours.

              Note that SMART Automatic Offline Testing is not part of the ATA
              Specification.  Please see the smartctl -o  command-line  option
              documentation for further information about this feature.

       -S VALUE
              Enables or disables Attribute Autosave when smartd starts up and
              has  no  further  effect.  The valid arguments to this Directive
              are on and off.  Also affects SCSI  devices.   [Please  see  the
              smartctl -S command-line option.]

       -H     [ATA]  Check the health status of the disk with the SMART RETURN
              STATUS command.  If this command reports a failing  health  sta‐
              tus, then disk failure is predicted in less than 24 hours, and a
              message  at  loglevel  'LOG_CRIT'  will  be  logged  to  syslog.
              [Please see the smartctl -H command-line option.]

              [NVMe] Checks the "Critical Warning" byte from the  SMART/Health
              Information  log.   If  any  warning  bit  is  set, a message at
              loglevel 'LOG_CRIT' will be logged to syslog.

       -l TYPE
              Reports increases in the number of errors in one of three  SMART
              logs.  The valid arguments to this Directive are:

              error - [ATA] report if the number of ATA errors reported in the
              Summary SMART error log has increased since the last check.

              error  -  [NVMe]  report if the "Number of Error Information Log
              Entries" from the SMART/Health  Information  log  has  increased
              since the last check.
              [NEW  EXPERIMENTAL  SMARTD 7.4 FEATURE] This will only be logged
              as LOG_CRIT if at least one of the new errors is  still  present
              in  the  Error Information log and its status indicates a device
              related error.  Up to eight of the most recent of  these  errors
              are  logged  as  LOG_INFO then.  This is useful because the NVMe
              Error Information log is not persistent across power  cycles  or
              device resets.
              If all new errors are either no longer present in the log or are
              not  device related (e.g. invalid command, invalid field in com‐
              mand, ...), a  LOG_INFO  message  is  generated  instead.   This
              avoids misleading warnings if the operating system issues unsup‐
              ported  commands and the device firmware also logs these kind of
              errors.

              xerror - [ATA] report if the number of ATA  errors  reported  in
              the  Extended  Comprehensive SMART error log has increased since
              the last check.

              If both '-l error' and '-l xerror' are specified, smartd  checks
              the maximum of both values.

              [Please see the smartctl -l xerror command-line option.]

              xerror - [NVMe] same as '-l error'.

              selftest  - report if the number of failed tests reported in the
              SMART Self-Test Log has increased since the last  check,  or  if
              the  timestamp  associated  with the most recent failed test has
              increased.  Note that such errors will only be logged if you run
              self-tests on the disk (and it fails a test!).   Self-Tests  can
              be  run  automatically  by smartd: please see the '-s' Directive
              below.  Self-Tests can also be run manually  by  using  the  '-t
              short'  and '-t long' options of smartctl and the results of the
              testing can be observed using the  smartctl  '-l selftest'  com‐
              mand-line  option.   [Please see the smartctl -l and -t command-
              line options.]

              [ATA only] Failed self-tests outdated by a newer successful  ex‐
              tended  self-test are ignored.  The warning email counter is re‐
              set if the number of failed self tests dropped to 0.  This typi‐
              cally happens when an extended self-test is run  after  all  bad
              sectors have been reallocated.

              offlinests[,ns]  - [ATA only] report if the Offline Data Collec‐
              tion status has changed since the last check.  The  report  will
              be  logged  as  LOG_CRIT  if  the new status indicates an error.
              With some drives the status often  changes,  therefore  '-l  of‐
              flinests' is not enabled by '-a' Directive.  Appending ',ns' (no
              standby) to this directive is not implemented on Linux.

              selfteststs[,ns]  - [ATA only] report if the Self-Test execution
              status has changed since the last check.   The  report  will  be
              logged  as  LOG_CRIT  if the new status indicates an error.  Ap‐
              pending ',ns' (no standby) to this directive is not  implemented
              on Linux.

              scterc,READTIME,WRITETIME - [ATA only] sets the SCT Error Recov‐
              ery  Control settings to the specified values (deciseconds) when
              smartd starts up and has no further effect.  Values of 0 disable
              the feature, other values less than 65  are  probably  not  sup‐
              ported.  For RAID configurations, this is typically set to 70,70
              deciseconds.   [Please  see  the smartctl -l scterc command-line
              option.]

       -e NAME[,VALUE]
              Sets non-SMART device settings when smartd starts up and has  no
              further effect.  [Please see the smartctl --set command-line op‐
              tion.]  Valid arguments are:

              aam,[N|off]  - [ATA only] Sets the Automatic Acoustic Management
              (AAM) feature.

              apm,[N|off] - [ATA only]  Sets  the  Advanced  Power  Management
              (APM) feature.

              lookahead,[on|off]  -  [ATA  only] Sets the read look-ahead fea‐
              ture.

              security-freeze - [ATA only] Sets ATA Security feature to frozen
              mode.

              standby,[N|off] - [ATA only] Sets the standby  (spindown)  timer
              and places the drive in the IDLE mode.

              wcache,[on|off]  - [ATA only] Sets the volatile write cache fea‐
              ture.

              dsn,[on|off] - [ATA only] Sets the DSN feature.

       -s REGEXP
              Run Self-Tests or Offline Immediate Tests, at  scheduled  times.
              A  Self- or Offline Immediate Test will be run at the end of pe‐
              riodic device polling,  if  all  12  characters  of  the  string
              T/MM/DD/d/HH  match  the  extended  regular  expression  REGEXP.
              Here:

              T   is the type of the test.  The values that smartd will try to
                  match (in turn) are: 'L' for a Long  Self-Test,  'S'  for  a
                  Short  Self-Test, 'C' for a Conveyance Self-Test (ATA only),
                  and 'O' for an Offline Immediate Test (ATA only).   As  soon
                  as  a  match is found, the test will be started and no addi‐
                  tional matches will be  sought  for  that  device  and  that
                  polling cycle.

                  To  run  scheduled  Selective  Self-Tests,  use 'n' for next
                  span, 'r' to redo last span, or 'c' to  continue  with  next
                  span  or  redo  last span based on status of last test.  The
                  LBA range is based on the first span  from  the  last  test.
                  See the smartctl -t select,[next|redo|cont] options for fur‐
                  ther info.

                  Some disks (e.g. WD) do not preserve the selective self test
                  log across power cycles.  If state persistence ('-s' option)
                  is  enabled,  the  last test span is preserved by smartd and
                  used if (and only if) the selective self test log is empty.

              MM  is the month of the year, expressed with two decimal digits.
                  The range is from 01 (January) to 12  (December)  inclusive.
                  Do  not  use a single decimal digit or the match will always
                  fail!

              DD  is the day of the month, expressed with two decimal  digits.
                  The  range  is from 01 to 31 inclusive.  Do not use a single
                  decimal digit or the match will always fail!

              d   is the day of the week, expressed with  one  decimal  digit.
                  The range is from 1 (Monday) to 7 (Sunday) inclusive.

              HH  is the hour of the day, written with two decimal digits, and
                  given in hours after midnight.  The range is 00 (midnight to
                  just  before  1 am) to 23 (11pm to just before midnight) in‐
                  clusive.  Do not use a single decimal  digit  or  the  match
                  will always fail!

              If  the  regular expression contains substrings of the form :NNN
              or :NNN-LLL, where NNN and LLL are three decimal  digits,  stag‐
              gered tests are enabled.  Then a test will also be run if all 16
              (or   20)   characters   of   the  string  T/MM/DD/d/HH:NNN  (or
              T/MM/DD/d/HH:NNN-LLL) match the regular expression.  This  check
              is  done  for  up to seven :NNN or :NNN-LLL found in the regular
              expression.  The time used for the check is adjusted to the past
              such that tests of the first drive are not delayed, tests of the
              second drive are delayed by NNN hours, tests of the third  drive
              are delayed by 2*NNN hours, and so on.
              If  LLL  is  also  specified, delays are limited to LLL hours by
              calculating each individual delay as:
              '((DRIVE_INDEX * NNN) mod (LLL + 1))'.

              Some examples follow.  In reading these, keep in  mind  that  in
              extended  regular expressions a dot '.' matches any single char‐
              acter, and a parenthetical expression such as '(A|B|C)'  denotes
              any one of the three possibilities A, B, or C.

              To schedule a short Self-Test between 2–3 am every morning, use:
               -s S/../.././02
              To  schedule  a long Self-Test between 4–5 am every Sunday morn‐
              ing, use:
               -s L/../../7/04
              To enable staggered tests with delays in three hour steps, use:
               -s L/../../7/04:003
              To enable staggered tests with delays 0, 3, 6, 9, 1, 4,  7,  10,
              2, 5, 8, 0, ... hours, use:
               -s L/../../7/04:003-010
              To  enable  staggered  tests with delays 0, 1, 2, ..., 9, 10, 0,
              ... hours, use:
               -s L/../../7/04:001-010
              To schedule a long Self-Test between 10–11 pm on the  first  and
              fifteenth day of each month, use:
               -s L/../(01|15)/./22
              To  schedule  an  Offline Immediate test after every midnight, 6
              am, noon, and 6 pm, plus a Short Self-Test daily at 1–2 am and a
              Long Self-Test every Saturday at 3–4 am, use:
               -s (O/../.././(00|06|12|18)|S/../.././01|L/../../6/03)
              To enable staggered Long Self-Tests with delays  in  three  hour
              steps, use:
               -s (O/../.././(00|06|12|18)|S/../.././01|L/../../6/03:003)
              If  Long Self-Tests of a large disks take longer than the system
              uptime, a full disk test can be performed by  several  Selective
              Self-Tests.   To setup a full test of a 1 TB disk within 20 days
              (one 50 GB span each day), run this command once:
                smartctl -t select,0-99999999 /dev/sda
              To run the next test spans on Monday–Friday  between  12–13  am,
              run smartd with this directive:
               -s n/../../[1-5]/12

              Scheduled  tests  are  run  immediately following the regularly-
              scheduled device polling, if the current local date,  time,  and
              test type, match REGEXP.  By default the regularly-scheduled de‐
              vice  polling occurs every thirty minutes after starting smartd.
              Take caution if you use the '-i' option to make this polling in‐
              terval more than sixty minutes: the poll times may fail to coin‐
              cide with any of the testing times that you have specified  with
              REGEXP.   In  this  case the test will be run following the next
              device polling.

              Before running an offline or self-test, smartd checks to be sure
              that a self-test is not already running.  If a self-test is  al‐
              ready  running,  then  this running self test will not be inter‐
              rupted to begin another test.

              smartd will not attempt to run any type of test if another  test
              was already started or run in the same hour.

              To  avoid  performance  problems during system boot, smartd will
              not attempt to run any scheduled tests following the very  first
              device polling (unless '-q onecheck' is specified).

              Each  time  a  test  is run, smartd will log an entry to SYSLOG.
              You can use these or the '-q showtests' command-line  option  to
              verify  that you constructed REGEXP correctly.  The matching or‐
              der (L before S before C before O) ensures that if multiple test
              types are all scheduled for the same hour, the longer test  type
              has precedence.  This is usually the desired behavior.

              If  the  scheduled tests are used in conjunction with state per‐
              sistence ('-s' option), smartd will also try to match the  hours
              since  last  shutdown  (or  90 days at most).  If any test would
              have been started during downtime, the longest  (see  above)  of
              these tests is run after second device polling.

              If  the  '-n'  directive  is  used  and any test would have been
              started during disk standby time, the longest of these tests  is
              run when the disk is active again.

              Unix  users:  please  beware that the rules for extended regular
              expressions [regex(7)] are not the same as the rules  for  file-
              name pattern matching by the shell [glob(7)].  smartd will issue
              harmless informational warning messages if it detects characters
              in  REGEXP  that appear to indicate that you have made this mis‐
              take.

       -m ADD Send a warning email to the email address ADD if the  '-H',  '-l
              error',  '-l  xerror',  '-l selftest', '-f', '-C', '-U', or '-W'
              Directives detect a failure or a new error, or if a  SMART  com‐
              mand  to  the disk fails.  This Directive only works in conjunc‐
              tion with these other Directives (or with the equivalent default
              '-a' Directive).

              To prevent your email in-box from getting filled up with warning
              messages, by default only a single  warning  and  (depending  on
              '-s'  option) daily reminder emails will be sent for each of the
              enabled alert types.  See the '-M' Directive below for details.

              To send email to more than one user, please  use  the  following
              "comma      separated"      form      for      the      address:
              user1@add1,user2@add2,...,userN@addN (with no spaces).

              To test that email is being sent correctly, use  the  '-M  test'
              Directive  described  below  to  send  one test email message on
              smartd startup.

              By default, email is sent using the system mail(1) command.   In
              order that smartd find this command (normally /usr/bin/mail) the
              executable  must be in the path of the shell or environment from
              which smartd was started.  If you wish to  specify  an  explicit
              path to the mail executable (for example /usr/local/bin/mail) or
              a  custom  script to run, please use the '-M exec' Directive be‐
              low.

              Note also that there is a special argument <nomailer> which  can
              be given to the '-m' Directive in conjunction with the '-M exec'
              Directive.  Please see below for an explanation of its effect.

              If the mailer or the shell running it produces any STDERR/STDOUT
              output,  then a snippet of that output will be copied to SYSLOG.
              The remainder of the output is discarded.  If problems  are  en‐
              countered  in  sending  mail, this should help you to understand
              and fix them.  If you have mail problems, we  recommend  running
              smartd in debug mode with the '-d' flag, using the '-M test' Di‐
              rective described below.

              If  a word of the comma separated list has the form '@plugin', a
              custom script /etc/smartmontools/smartd_warning.d/plugin is  run
              and  the word is removed from the list before sending mail.  The
              string 'plugin' may be any valid name except 'ALL'.   If  '@ALL'
              is  specified,  all  scripts  in /etc/smartmontools/smartd_warn‐
              ing.d/*  are  run  instead.   This  is  handled  by  the  script
              /usr/share/smartmontools/smartd_warning.sh  (see  also '-M exec'
              below).  Plugin scripts without execute permission are  silently
              ignored.   If  any  plugin  script  is  missing  or fails with a
              nonzero exit status, the warning script exits immediately  with‐
              out sending mail.

       -M TYPE
              These  Directives  modify the behavior of the smartd email warn‐
              ings enabled with the  '-m'  email  Directive  described  above.
              These '-M' Directives only work in conjunction with the '-m' Di‐
              rective and can not be used without it.

              Multiple  -M  Directives  may be given.  If more than one of the
              following three -M Directives are given  (example:  -M  once  -M
              daily) then the final one (in the example, -M daily) is used.

              The  valid arguments to the -M Directive are (one of the follow‐
              ing three):

              once - send only one warning email for each type of disk problem
              detected.  This is the default unless  state  persistence  ('-s'
              option) is enabled.

              always  -  [NEW EXPERIMENTAL SMARTD 7.4 FEATURE] send additional
              warning reminder emails, upon each check, for each type of  disk
              problem detected.

              daily  -  send additional warning reminder emails, once per day,
              for each type of disk problem detected.  This is the default  if
              state persistence ('-s' option) is enabled.

              diminishing  -  send additional warning reminder emails, after a
              one-day interval, then a two-day interval, then a  four-day  in‐
              terval,  and so on for each type of disk problem detected.  Each
              interval is twice as long as the previous interval.
              [NEW EXPERIMENTAL SMARTD 7.4 FEATURE] The interval  length  will
              stay at 32 days after 5 warning reminder emails.

              If  a  disk  problem  is  no longer detected, the internal email
              counter is reset.  If the problem reappears a new warning  email
              is sent immediately.

              In  addition,  one  may add zero or more of the following Direc‐
              tives:

              test - send a single test email immediately upon smartd startup.
              This allows one to verify that  email  is  delivered  correctly.
              Note  that  if this Directive is used, smartd will also send the
              normal email warnings that were enabled with the '-m' Directive,
              in addition to the single test email!

              exec PATH - run the executable PATH instead of the default  mail
              command, when smartd needs to send email.  PATH must point to an
              executable binary file or script.

              By  setting  PATH  to point to a customized script, you can make
              smartd perform useful tricks when a  disk  problem  is  detected
              (beeping  the  console,  shutting down the machine, broadcasting
              warnings to all logged-in users, etc.)  But please  be  careful.
              smartd  will block until the executable PATH returns, so if your
              executable hangs, then  smartd  will  also  hang.   Some  sample
              scripts are included in /usr/share/doc/smartmontools/examples//.

              The  exit status of the executable is recorded by smartd in SYS‐
              LOG.  The executable is not  expected  to  write  to  STDOUT  or
              STDERR.  If it does, then this is interpreted as indicating that
              something is going wrong with your executable, and a fragment of
              this  output  is  logged to SYSLOG to help you to understand the
              problem.  Normally, if you wish to leave some record behind, the
              executable should send mail or write to a file or device.

              Before running the executable, smartd sets a number of  environ‐
              ment variables.  These environment variables may be used to con‐
              trol  the  executable's behavior.  The environment variables ex‐
              ported by smartd are:

              SMARTD_MAILER
                  is set to the argument of -M exec, if  present  or  else  to
                  'mail' (examples: /usr/local/bin/mail, mail).

              SMARTD_DEVICE
                  is set to the device path (example: /dev/sda).

              SMARTD_DEVICETYPE
                  is  set  to  the  device type specified by '-d' directive or
                  'auto' if none.

              SMARTD_DEVICESTRING
                  is set to the device description.  It starts with SMARTD_DE‐
                  VICE and may be followed by an optional controller identifi‐
                  cation (example: /dev/sda [SAT]).  The string may contain  a
                  space and is NOT quoted.

              SMARTD_DEVICEINFO
                  is  set to device identify information.  It includes most of
                  the info printed by smartctl -i but uses a brief single line
                  format.  This device info is also logged when smartd  starts
                  up.  The string contains space characters and is NOT quoted.

              SMARTD_FAILTYPE
                  gives the reason for the warning or message email.  The pos‐
                  sible values that it takes and their meanings are:
                  EmailTest: this is an email test message.
                  Health: the SMART health status indicates imminent failure.
                  Usage: a usage Attribute has failed.
                  SelfTest: the number of self-test failures has increased.
                  ErrorCount:  the  number  of errors in the ATA error log has
                  increased.
                  CurrentPendingSector: one of more disk sectors could not  be
                  read  and  are marked to be reallocated (replaced with spare
                  sectors).
                  OfflineUncorrectableSector:  during  off-line  testing,   or
                  self-testing, one or more disk sectors could not be read.
                  Temperature:  Temperature reached critical limit (see -W di‐
                  rective).
                  FailedHealthCheck: the SMART health status command failed.
                  FailedReadSmartData: the command  to  read  SMART  Attribute
                  data failed.
                  FailedReadSmartErrorLog: the command to read the SMART error
                  log failed.
                  FailedReadSmartSelfTestLog:  the  command  to read the SMART
                  self-test log failed.
                  FailedOpenDevice: the open() command to the device failed.

              SMARTD_ADDRESS
                  is determined by the address argument ADD of the '-m' Direc‐
                  tive.  If ADD is <nomailer>, then SMARTD_ADDRESS is not set.
                  Otherwise, it is set to the  comma-separated-list  of  email
                  addresses  given  by  the  argument ADD, with the commas re‐
                  placed by spaces (example:admin@example.com root).  If  more
                  than  one email address is given, then this string will con‐
                  tain space characters and is NOT quoted, so to use it  in  a
                  shell script you may want to enclose it in double quotes.

              SMARTD_ADDRESS_ORIG
                  is  set  to the original value of SMARTD_ADDRESS with '@plu‐
                  gin' strings still present.  If there are no such strings in
                  the '-m' Directive, this variable is NOT set.

              SMARTD_MESSAGE
                  is set to the one sentence  summary  warning  email  message
                  string  from  smartd.   This  message  string contains space
                  characters and is NOT quoted.  So to use $SMARTD_MESSAGE  in
                  a  shell  script  you  should  probably enclose it in double
                  quotes.

              SMARTD_FULLMESSAGE
                  is set to the contents of the entire email  warning  message
                  string  from smartd.  This message string contains space and
                  return  characters  and  is   NOT   quoted.    So   to   use
                  $SMARTD_FULLMESSAGE  in  a  shell script you should probably
                  enclose it in double quotes.

              SMARTD_TFIRST
                  is a text string giving the time and date at which the first
                  problem of this type was reported.  This  text  string  con‐
                  tains  space  characters and no newlines, and is NOT quoted.
                  For example:
                  Sun Feb  9 14:58:19 2003 CST

              SMARTD_TFIRSTEPOCH
                  is an integer, which is the unix epoch  (number  of  seconds
                  since Jan 1, 1970) for SMARTD_TFIRST.

              SMARTD_PREVCNT
                  is  an  integer  specifying  the number of previous messages
                  sent.  It is set to '0' for the first message.

              SMARTD_NEXTDAYS
                  is an integer specifying the number of days until  the  next
                  message  will be sent.  It is set to empty on '-M once', set
                  to '0' on '-M always' and set to '1' on '-M daily'.

              If the '-m ADD' Directive is given with a normal  address  argu‐
              ment,  then  the  executable pointed to by PATH will be run in a
              shell with STDIN receiving the body of the  email  message,  and
              with the same command-line arguments:
                -s "$SMARTD_SUBJECT" $SMARTD_ADDRESS
              that would normally be provided to 'mail'.  Examples include:
              -m user@home -M exec /usr/bin/mail
              -m admin@work -M exec /usr/local/bin/mailto
              -m root -M exec /Example_1/shell/script/below

              If  the '-m ADD' Directive is given with the special address ar‐
              gument <nomailer> then the executable pointed to by PATH is  run
              in  a shell with no STDIN and no command-line arguments, for ex‐
              ample:
                -m <nomailer> -M exec /Example_2/shell/script/below

              If the executable produces any STDERR/STDOUT output, then smartd
              assumes that something is going wrong, and  a  snippet  of  that
              output will be copied to SYSLOG.  The remainder of the output is
              then discarded.

              Some EXAMPLES of scripts that can be used with the '-M exec' Di‐
              rective  are given below.  Some sample scripts are also included
              in /usr/share/doc/smartmontools/examples//.

              The  executable  is  run  by  the  script   /usr/share/smartmon‐
              tools/smartd_warning.sh.   This  script formats subject and full
              message based on SMARTD_MESSAGE and other environment  variables
              set  by  smartd.   The  environment variables SMARTD_SUBJECT and
              SMARTD_FULLMESSAGE are set by the script before running the exe‐
              cutable.

       -f     [ATA only] Check for 'failure'  of  any  Usage  Attributes.   If
              these  Attributes  are  less  than or equal to the threshold, it
              does NOT indicate imminent disk failure.  It "indicates an advi‐
              sory condition where the usage or age of the device has exceeded
              its intended design life period."  [Please see the  smartctl  -A
              command-line option.]

       -p     [ATA  only]  Report anytime that a Prefail Attribute has changed
              its value since the last check.  [Please  see  the  smartctl  -A
              command-line option.]

       -u     [ATA only] Report anytime that a Usage Attribute has changed its
              value  since  the  last check.  [Please see the smartctl -A com‐
              mand-line option.]

       -t     [ATA only] Equivalent to turning on the two previous flags  '-p'
              and  '-u'.   Tracks  changes in all device Attributes (both Pre‐
              failure and Usage).  [Please see the  smartctl  -A  command-line
              option.]

       -i ID  [ATA  only]  Ignore device Attribute number ID when checking for
              failure of Usage Attributes.  ID must be a  decimal  integer  in
              the  range  from 1 to 255.  This Directive modifies the behavior
              of the '-f' Directive and has no effect without it.

              This is useful, for example, if you have a  very  old  disk  and
              don't  want to keep getting messages about the hours-on-lifetime
              Attribute (usually Attribute 9) failing.  This Directive may ap‐
              pear multiple times for a single device, if you want  to  ignore
              multiple Attributes.

       -I ID  [ATA  only]  Ignore device Attribute ID when tracking changes in
              the Attribute values.  ID must be a decimal integer in the range
              from 1 to 255.  This Directive  modifies  the  behavior  of  the
              '-p', '-u', and '-t' tracking Directives and has no effect with‐
              out one of them.

              This  is useful, for example, if one of the device Attributes is
              the disk temperature (usually Attribute 194 or 231).   It's  an‐
              noying  to  get reports each time the temperature changes.  This
              Directive may appear multiple times for a single device, if  you
              want to ignore multiple Attributes.

       -r ID[!]
              [ATA  only]  When tracking, report the Raw value of Attribute ID
              along with its (normally reported) Normalized value.  ID must be
              a decimal integer in the range from 1 to  255.   This  Directive
              modifies  the  behavior of the '-p', '-u', and '-t' tracking Di‐
              rectives and has no effect without one of them.  This  Directive
              may be given multiple times.

              A  common  use of this Directive is to track the device Tempera‐
              ture (often ID=194 or 231).

              If the optional flag '!' is appended, a change of the Normalized
              value is considered critical.  The  report  will  be  logged  as
              LOG_CRIT and a warning email will be sent if '-m' is specified.

       -R ID[!]
              [ATA  only]  When tracking, report whenever the Raw value of At‐
              tribute  ID  changes.   (Normally  smartd  only   tracks/reports
              changes of the Normalized Attribute values.)  ID must be a deci‐
              mal integer in the range from 1 to 255.  This Directive modifies
              the behavior of the '-p', '-u', and '-t' tracking Directives and
              has  no effect without one of them.  This Directive may be given
              multiple times.

              If this Directive is given, it automatically  implies  the  '-r'
              Directive  for  the same Attribute, so that the Raw value of the
              Attribute is reported.

              A common use of this Directive is to track the  device  Tempera‐
              ture (often ID=194 or 231).  It is also useful for understanding
              how  different  types  of  system behavior affects the values of
              certain Attributes.

              If the optional flag '!' is appended, a change of the Raw  value
              is  considered  critical.  The report will be logged as LOG_CRIT
              and a warning email will be sent if '-m' is specified.  An exam‐
              ple is '-R 5!' to warn when new sectors are reallocated.

       -C ID[+]
              [ATA only] Report if the current number of  pending  sectors  is
              non-zero.   Here  ID is the id number of the Attribute whose raw
              value is the Current Pending Sector count.  The allowed range of
              ID is 0 to 255 inclusive.   To  turn  off  this  reporting,  use
              ID = 0.   If  the -C ID option is not given, then it defaults to
              -C 197 (since Attribute 197 is generally used to monitor pending
              sectors).  If the name of this Attribute is  changed  by  a  '-v
              197,FORMAT,NAME' directive, the default is changed to -C 0.

              If  '+'  is specified, a report is only printed if the number of
              sectors has increased between two check cycles.  Some  disks  do
              not  reset this attribute when a bad sector is reallocated.  See
              also '-v 197,increasing' below.

              The warning email counter is reset if the number of pending sec‐
              tors dropped to 0.  This typically happens when all pending sec‐
              tors have been reallocated or could be read again.

              A pending sector is a disk sector (containing 512 bytes of  your
              data)  which  the device would like to mark as "bad" and reallo‐
              cate.  Typically this is because your  computer  tried  to  read
              that sector, and the read failed because the data on it has been
              corrupted  and  has  inconsistent  Error Checking and Correction
              (ECC) codes.  This is important to know, because it  means  that
              there  is some unreadable data on the disk.  The problem of fig‐
              uring out what file this data belongs to is operating system and
              file system specific.  You can typically force the sector to re‐
              allocate by writing to it (translation: make the device  substi‐
              tute  a  spare  good sector for the bad one) but at the price of
              losing the 512 bytes of data stored there.

       -U ID[+]
              [ATA only] Report if the number of offline uncorrectable sectors
              is non-zero.  Here ID is the id number of  the  Attribute  whose
              raw  value  is  the Offline Uncorrectable Sector count.  The al‐
              lowed range of ID is 0 to 255 inclusive.  To turn off  this  re‐
              porting,  use ID = 0.  If the -U ID option is not given, then it
              defaults to -U 198 (since Attribute 198  is  generally  used  to
              monitor offline uncorrectable sectors).  If the name of this At‐
              tribute  is  changed  by  a  '-v  198,FORMAT,NAME'  (except  '-v
              198,FORMAT,Offline_Scan_UNC_SectCt'), directive, the default  is
              changed to -U 0.

              If  '+'  is specified, a report is only printed if the number of
              sectors has increased since the last check cycle.  Some disks do
              not reset this attribute when a bad sector is reallocated.   See
              also '-v 198,increasing' below.

              The  warning email counter is reset if the number of offline un‐
              correctable sectors dropped to 0.  This typically  happens  when
              all offline uncorrectable sectors have been reallocated or could
              be read again.

              An  offline  uncorrectable sector is a disk sector which was not
              readable during an off-line scan or a self-test.  This is impor‐
              tant to know, because if you have data stored in this disk  sec‐
              tor,  and  you  need to read it, the read will fail.  Please see
              the previous '-C' option for more details.

       -W DIFF[,INFO[,CRIT]]
              Report if the current temperature had changed by at  least  DIFF
              degrees  since  last report, or if new min or max temperature is
              detected.  Report or Warn if the temperature is greater or equal
              than one of INFO or CRIT degrees Celsius.  If the limit CRIT  is
              reached,  a  message  with loglevel 'LOG_CRIT' will be logged to
              syslog and a warning email will be send if  '-m'  is  specified.
              If  only  the  limit  INFO  is  reached, a message with loglevel
              'LOG_INFO' will be logged.

              The warning email counter is reset if  the  temperature  dropped
              below INFO or CRIT-5 if INFO is not specified.

              If  this directive is used in conjunction with state persistence
              ('-s' option), the min and max temperature values are  preserved
              across  boot  cycles.   The minimum temperature value is not up‐
              dated during the first 30 minutes after startup.

              To disable any of the 3 reports, set the corresponding limit  to
              0.   Trailing  zero  arguments  may be omitted.  By default, all
              temperature reports are disabled ('-W 0').

              To track temperature changes of at least 2 degrees, use:
              -W 2
              To log informal messages on temperatures of at least 40 degrees,
              use:
              -W 0,40
              For warning messages/mails on temperatures of at  least  45  de‐
              grees, use:
              -W 0,0,45
              To combine all of the above reports, use:
              -W 2,40,45

              For  ATA devices, smartd interprets Attribute 194 or 190 as Tem‐
              perature Celsius by default.  This can be changed to Attribute 9
              or 220 by the drive database  or  by  the  '-v  9,temp'  or  '-v
              220,temp' directive.

              For  NVMe  devices,  smartd  checks the maximum of the Composite
              Temperature value and all Temperature Sensor values reported  by
              SMART/Health Information log.

       -F TYPE
              [ATA  only]  Modifies  the  behavior of smartd to compensate for
              some known and understood device firmware bug.   This  directive
              may be used multiple times.  The valid arguments are:

              none  - Assume that the device firmware obeys the ATA specifica‐
              tions.  This is the default, unless the device has  presets  for
              '-F'  in the drive database.  Using this directive will override
              any preset values.

              nologdir - Suppresses read attempts of SMART or  GP  Log  Direc‐
              tory.   Support  for all standard logs is assumed without an ac‐
              tual check.  Some Intel SSDs may freeze  if  log  address  0  is
              read.

              samsung - In some Samsung disks (example: model SV4012H Firmware
              Version:  RM100-08) some of the two- and four-byte quantities in
              the SMART data structures are byte-swapped (relative to the  ATA
              specification).   Enabling  this option tells smartd to evaluate
              these quantities in byte-reversed order.  Some signs  that  your
              disk  needs  this  option are (1) no self-test log printed, even
              though you have run self-tests; (2) very large  numbers  of  ATA
              errors reported in the ATA error log; (3) strange and impossible
              values for the ATA error log timestamps.

              samsung2  -  In  some Samsung disks the number of ATA errors re‐
              ported is byte swapped.  Enabling this option  tells  smartd  to
              evaluate this quantity in byte-reversed order.

              samsung3  -  Some  Samsung disks (at least SP2514N with Firmware
              VF100-37) report a self-test still in progress with 0% remaining
              when the test was already completed.  If this directive is spec‐
              ified, smartd will not skip the next  scheduled  self-test  (see
              Directive '-s' above) in this case.

              xerrorlba - This only affects smartctl.

              [Please see the smartctl -F command-line option.]

       -v ID,FORMAT[:BYTEORDER][,NAME]
              [ATA only] Sets a vendor-specific raw value print FORMAT, an op‐
              tional  BYTEORDER  and  an optional NAME for Attribute ID.  This
              directive may be used multiple times.  Please  see  smartctl  -v
              command-line option for further details.

              The following arguments affect smartd warning output:

              197,increasing  - Raw Attribute number 197 (Current Pending Sec‐
              tor Count) is not reset if  uncorrectable  sectors  are  reallo‐
              cated.  This sets '-C 197+' if no other '-C' directive is speci‐
              fied.

              198,increasing - Raw Attribute number 198 (Offline Uncorrectable
              Sector  Count) is not reset if uncorrectable sectors are reallo‐
              cated.  This sets '-U 198+' if no other '-U' directive is speci‐
              fied.

       -P TYPE
              [ATA only] Specifies whether smartd should use  any  preset  op‐
              tions that are available for this drive.  The valid arguments to
              this Directive are:

              use  -  use any presets that are available for this drive.  This
              is the default.

              ignore - do not use any presets for this drive.

              show - show the presets listed for this drive in the database.

              showall - show the presets that are available for all drives and
              then exit.

              [Please see the smartctl -P command-line option.]

       -a     Equivalent to turning on all of the following  Directives:  '-H'
              to check the SMART health status, '-f' to report failures of Us‐
              age  (rather  than Prefail) Attributes, '-t' to track changes in
              both Prefailure and Usage Attributes, '-l error' to  report  in‐
              creases in the number of ATA errors, '-l selftest' to report in‐
              creases  in the number of Self-Test Log errors, '-l selfteststs'
              to report changes of Self-Test execution status, '-C 197' to re‐
              port nonzero values of the current pending sector count, and '-U
              198' to report nonzero values  of  the  offline  pending  sector
              count.

              Note  that  -a is the default for ATA devices.  If none of these
              other Directives is given, then -a is assumed.

       -c OPTION=VALUE
              Allows one to override smartd command line options for  specific
              devices.  Only the following OPTION is currently supported:

       -c i=N, -c interval=N
              [NEW  EXPERIMENTAL SMARTD 7.3 FEATURE] Sets the interval between
              disk checks to N seconds, where N is  a  decimal  integer.   The
              minimum allowed value is ten.  The default is the value from the
              '-i  N, --interval=N' command line option or its default of 1800
              seconds.

       #      Comment: ignore the remainder of the line.

       \      Continuation character: if this is the last  non-white  or  non-
              comment  character  on a line, then the following line is a con‐
              tinuation of the current one.

       If you are not sure which Directives to use,  I  suggest  experimenting
       for  a  few  minutes with smartctl to see what SMART functionality your
       disk(s) support(s).  If you do not like voluminous syslog  messages,  a
       good choice of smartd configuration file Directives might be:
       -H -l selftest -l error -f.
       If you want more frequent information, use: -a.


       EXAMPLES OF SHELL SCRIPTS FOR '-M exec'
              These  are  two  examples of shell scripts that can be used with
              the '-M exec PATH' Directive described previously.  The paths to
              these scripts and similar executables is the  PATH  argument  to
              the '-M exec PATH' Directive.

              Example  1:  This  script  is  for  use with '-m ADDRESS -M exec
              PATH'.  It appends the output of smartctl -a to  the  output  of
              the smartd email warning message and sends it to ADDRESS.

              #! /bin/sh

              # Save the email message (STDIN) to a file:
              cat > /root/msg

              # Append the output of smartctl -a to the message:
              /usr/sbin/smartctl -a -d $SMART_DEVICETYPE \
                $SMARTD_DEVICE >> /root/msg

              # Now email the message to the user at address ADD:
              /usr/bin/mail -s "$SMARTD_SUBJECT" $SMARTD_ADDRESS \
                < /root/msg

              Example  2:  This  script is for use with '-m <nomailer> -M exec
              PATH'.  It warns all users about a disk problem, waits  30  sec‐
              onds, and then powers down the machine.

              #! /bin/sh

              # Warn all users of a problem
              wall <<EOF
              Problem detected with disk: $SMARTD_DEVICESTRING
              Warning message from smartd is: $SMARTD_MESSAGE
              Shutting down machine in 30 seconds...
              EOF

              # Wait half a minute
              sleep 30

              # Power down the machine
              /sbin/shutdown -hf now

              Some  example  scripts  are  distributed  with the smartmontools
              package, in /usr/share/doc/smartmontools/examples/.

              Please note that these scripts typically run  as  root,  so  any
              files  that  they  read/write should not be writable by ordinary
              users or reside in directories like /tmp that  are  writable  by
              ordinary users and may expose your system to symlink attacks.

              As  previously  described,  if  the  scripts  write to STDOUT or
              STDERR, this is interpreted as indicating that there was an  in‐
              ternal  error  within the script, and a snippet of STDOUT/STDERR
              is logged to SYSLOG.  The remainder is flushed.


FILES
       /etc/smartd.conf
              full path of this file.


SEE ALSO
       smartd(8), smartctl(8), mail(1), regex(7).


PACKAGE VERSION
       smartmontools-7.4 2023-08-01 r5530
       $Id: smartd.conf.5.in 5521 2023-07-24 16:44:49Z chrfranke $

smartmontools-7.4                 2023-08-01                    SMARTD.CONF(5)