Home | man(8)


DMEVENTD(8)                 System Manager's Manual                DMEVENTD(8)

NAME
       dmeventd — Device-mapper event daemon

SYNOPSIS
       dmeventd [-d [-d [-d]]] [-e exit_on_path] [-f] [-h] [-i] [-l] [-R] [-V]
       [-?]

DESCRIPTION
       dmeventd is the event monitoring daemon for device-mapper devices.  Li‐
       brary plugins can register and carry out actions triggered when partic‐
       ular events occur.

OPTIONS
       -d     Repeat  from 1 to 3 times (-d, -dd, -ddd) to increase the detail
              of debug messages sent to syslog.  Each extra d adds more debug‐
              ging information.

       -e exit_on_path
              Specifies the file path whose presence is checked by the  daemon
              when  it  receives a signal (SIGINT, SIGTERM) and allows to exit
              even if there are still monitored devices.  This can  help  with
              system  shutdown  where  devices have not been unmonitored prop‐
              erly.  To disable this behavior set this to the empty string "".
              Default value is "/run/nologin".

       -f     Don't fork, run in the foreground.

       -h     Show help information.

       -i     Query the running daemon instance for  the  status  information.
              The  format  is internal and unstable and it is targeted for de‐
              velopers.  Format may change between versions.

       -l     Log through stdout and stderr instead of  syslog.   This  option
              works only with option -f, otherwise it is ignored.

       -?     Show help information on stderr.

       -R     Replace  a  running dmeventd instance. The running dmeventd must
              be version 2.02.77 or newer. The new dmeventd instance will  ob‐
              tain  a list of devices and events to monitor from the currently
              running daemon.

       -V     Show version of dmeventd.

LVM PLUGINS
       Mirror Attempts to handle device failure automatically.
              See lvm.conf(5).

       Raid   Attempts to handle device failure automatically.
              See lvm.conf(5).

       Snapshot
              Monitors how full a snapshot is becoming and emits a warning  to
              syslog  when  it exceeds 80% full.  The warning is repeated when
              85%, 90% and 95% of the snapshot is  filled.   See  lvm.conf(5).
              Snapshot  which  runs  out  of space gets invalid and when it is
              mounted, it gets umounted if possible.

       Thin   Monitors how full a thin pool data and metadata is becoming  and
              emits a warning to syslog when it exceeds 80% full.  The warning
              is  repeated when more than 85%, 90% and 95% of the thin pool is
              filled. See lvm.conf(5).  When a thin pool fills over 50%  (data
              or  metadata) thin plugin calls configured dmeventd/thin_command
              with every 5% increase.  With default setting it calls  internal
              lvm  lvextend  --use-policies to resize thin pool when it's been
              filled above configured  threshold  activation/thin_pool_autoex‐
              tend_threshold.  If the command fails, dmeventd thin plugin will
              keep  retrying  execution with increasing time delay between re‐
              tries up to 42 minutes.  User may also configure  external  com‐
              mand  to  support more advanced maintenance operations of a thin
              pool.  Such external command can e.g. remove some unneeded snap‐
              shots, use fstrim(8) to free recover space in a thin  pool,  but
              also  can  use lvextend --use-policies if other actions have not
              released enough space.  Command is executed  with  environmental
              variable  LVM_RUN_BY_DMEVENTD=1  so any lvm2 command executed in
              this environment will not try to interact with dmeventd.  To see
              the fullness of a thin pool command may check these two environ‐
              mental variables DMEVENTD_THIN_POOL_DATA and DMEVENTD_THIN_POOL_
              METADATA.  Command can also read status with tools like lvs(8).

       Vdo    Monitors how full a VDO pool data is becoming and emits a  warn‐
              ing to syslog when it exceeds 80% full.  The warning is repeated
              when  more  than 85%, 90% and 95% of the VDO pool is filled. See
              lvm.conf(5).  When a VDO pool fills over 50%  vdo  plugin  calls
              configured  dmeventd/vdo_command  with  every 5% increase.  With
              default setting it calls internal lvm lvextend --use-policies to
              resize VDO pool when  it's  been  filled  above  the  configured
              threshold activation/vdo_pool_autoextend_threshold.  If the com‐
              mand  fails,  dmeventd  vdo  plugin will keep retrying execution
              with increasing time delay between retries  up  to  42  minutes.
              User  may  also  configure  external command to support more ad‐
              vanced maintenance operations of a VDO pool.  Such external com‐
              mand can e.g. remove some unneeded  space  with  fstrim(8),  but
              also  can  use lvextend --use-policies if other actions have not
              released enough space.  Command is executed  with  environmental
              variable  LVM_RUN_BY_DMEVENTD=1  so any lvm2 command executed in
              this environment will not try to interact with dmeventd.  To see
              the fullness of a VDO pool command may check this  environmental
              variable  DMEVENTD_VDO_POOL.   Command can also read status with
              tools like lvs(8).

ENVIRONMENT VARIABLES
       DMEVENTD_THIN_POOL_DATA
              Variable is set by thin plugin and is available to executed pro‐
              gram.  Value present actual usage  of  thin  pool  data  volume.
              Variable is not set when error event is processed.

       DMEVENTD_THIN_POOL_METADATA
              Variable is set by thin plugin and is available to executed pro‐
              gram.   Value present actual usage of thin pool metadata volume.
              Variable is not set when error event is processed.

       DMEVENTD_VDO_POOL
              Variable is set by vdo plugin and is available to executed  pro‐
              gram.   Value  present  actual  usage  of  VDO pool data volume.
              Variable is not set when error event is processed.

       LVM_RUN_BY_DMEVENTD
              Variable is set by thin and vdo plugin to prohibit recursive in‐
              teraction with dmeventd by any  executed  lvm2  command  from  a
              thin_command, vdo_command environment.

SEE ALSO
       lvm(8), lvm.conf(5), lvextend(8),
       fstrim(8)

Red Hat Inc            DM TOOLS 2.03.31(2) (2025-02-27)            DMEVENTD(8)